track is 4 seconds
z Speed Range1 to 8 from the fastest to the lowest. Any speed outside the range will be referred as
the 1st class; the range of the dwelling time is1 to 255.
z When the No. N preset point is set as No. 0, then all preset points before the No. N preset point in
the track will be valid however all numbers of preset points afterward and their speed and dwelling
time shall be set as 0 automatically.
z After tracks are edited, press OFF to store and exit while push the joystick to exit without storage.
6. Run Cruise Track: [SHOT]+[N]+ [Enter]
DisplayInput Tour No01
DescriptionN –– No. of the track from 1 to 6.
FunctionTour the No. N track and stop tour by pushing the joystick.
7. Stop Cruise Track: [SHOT]+[N]+ [OFF]
DisplayInput Tour No01
DescriptionN –– No. of the track from 1 to 6.
FunctionStop the No. N track or stop tour by pushing the joystick.
8. Cancel Cruise Track: [SHOT]+[N]+ [OFF] (Pressing [OFF] down until “ Clear Tour OK ”appears)
DisplayInput Tour No01
DescriptionN –– No. of the track from 1 to 6.
FunctionDelete the No. N track
9. Auto Pan ON (Operation of COP-2 Protocol): [AUTO]+[P1]+[ON]+[P2]+[OFF]
DisplayInput 1st No001
DescriptionP1–––– the starting scan No. of preset point from 1 to 128, which should be set already.
DisplayInput 2nd No002
DescriptionP2–––– the ending scan No. of preset point from 1 to 128, which should be set already.
If P1 = P2 or P1 and P2 are coincided, the speed dome will make scan in range of 360°.
Note:
(1) For PELCO-D and PELCO-P Protocols the way of operation is as follows:
Set the Starting Scan Position: Transfer the speed dome to the starting scan position, operation
[AUTO]+[ON]
Set the Ending Scan Position: Transfer the speed dome to the ending scan position, operation
[AUTO]+[OFF]
Run Auto Pan[AUTO]+[ENTER]
(2) Auto Pan operation takes the following parameters. You must set these parameters before using a
Auto Pan command to begin the scan operation. You can use the scan Stop command or PT scan stop
command to stop the scan. Setting scan condition:
z Auto Pan Position(First specify position, second specify position)
z Auto Pan Speed and Direction.
10. Stop Auto Pan[AUTO]+[OFF] (only for
COP-2 protocol)or push the joystick to stop scan.
11. Control the Zoom of the Camera[WIDE]/[TELE]
12. Control the Focus of the Camera[FAR]/[NEAR]
13. Control the Iris of the Camera[OPEN]/[CLOSE]
14. Auxiliary Control of the Camera By combination of [F1] and [ON], [OFF] buttons, you can set some
data of the camera, and functions are listed as follows
Definition of Keyboard Operation
No. of
Value N
Control Object
[F1]+N+[ON] [F1]+N+[OFF]
0 Camera Power Supply/Reset Control
Power ON/OFF
Switching
Camera Reset
Zobrazit stránku 7